 From: Mike Gagnon
  Where is Mike Gagnon?
 Pointe Claire
 Canada
 Mike Gagnon
 To: Barbara Peisch
  Where is Barbara Peisch?
 Oceanside
 California - United States
 Barbara Peisch
 Tags
Subject: RE: sys(1037) =programtically
Thread ID: 112422 Message ID: 112471 # Views: 1 # Ratings: 0
Version: Visual FoxPro 7 Category: Reports and Printers
Date: Wednesday, November 08, 2006 9:37:38 PM         
   


The DEFINES are only parameters that can be changed at will, so if you chnage the PD_ALLPAGES to 2, it run the program over and over, it will allways be 2.


> Sorry, but I don't see how this answers the question. First, Saifuddin asked for a technique that doesn't show a print dialog, and showing a print dialog is exactly what you're doing. And although this changes the structure of properties for the printer, I don't see any place where you're sending that to the printer. IOW, if you run the program again, it's showing the printer defaults, not the settings you selected.
>
> > You can change the struct if you know which values to change, for exmaple PD_ALLPAGES 0 means that the selection in Sys(1037) will be set to print all pages, if you change the value to 2 it will change that selection to printing a page range ect....
> >
> >
#Define PD_ALLPAGES 0
> > #Define PD_RETURNDC 256
> > #Define PD_USEDEVMODECOPIESANDCOLLATE 262144 && 0x40000
> > #Define PD_RETURNDEFAULT 1024 && 0x400
> > Do setPrinterPrompt
> > 
> > Local lcStruct, hDc, lnFlags
> > lnFlags = PD_USEDEVMODECOPIESANDCOLLATE + PD_RETURNDC
> > lcStruct = num2dword(66) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(lnFlags) +;
> >     num2word(65535) +;
> >     num2word(65535) +;
> >     num2word(1) +;
> >     num2word(65535) +;
> >     num2word(1) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0) +;
> >     num2dword(0)
> > If PrintDlg (@lcStruct) <> 0
> >     hDc = buf2dword (Substr (lcStruct, 17, 4))
> >     = DeleteDC (hDc)
> >     Messagebox("The user chose the print button")
> > Else
> >     Messagebox("The user chose the cancel button.")
> > Endif
> > 
> > Function num2dword (lnValue)
> > #Define m0 256
> > #Define m1 65536
> > #Define m2 16777216
> > Local b0, b1, b2, b3
> > b3 = Int(lnValue/m2)
> > b2 = Int((lnValue - b3 * m2)/m1)
> > b1 = Int((lnValue - b3*m2 - b2*m1)/m0)
> > b0 = Mod(lnValue, m0)
> > Return Chr(b0)+Chr(b1)+Chr(b2)+Chr(b3)
> > 
> > Function num2word (lnValue)
> > Return Chr(Mod(m.lnValue,256)) + Chr(Int(m.lnValue/256))
> > 
> > Function buf2dword (lcBuffer)
> > Return Asc(Substr(lcBuffer, 1,1)) + ;
> >     Asc(Substr(lcBuffer, 2,1)) * 256 +;
> >     Asc(Substr(lcBuffer, 3,1)) * 65536 +;
> >     Asc(Substr(lcBuffer, 4,1)) * 16777216
> > 
> > Procedure SetPrinterPrompt
> > Declare Integer DeleteDC In gdi32 Integer hdc
> > Declare Integer PrintDlg In comdlg32;
> >     STRING @ lppd

> >
> >
> > > Hi
> > >
> > > I want to programatically control the options of the dialog box which noramlly appears with the sys(1037).
> > >
> > > I do not want to use the sys(1037), instead change its settings from within the .prg file
> > >
> > > Is it possible, how.
> > >
> > > regards
> > > Saif

> >
> >
> >
> > Mike Gagnon
> >

>
>
>
> -BP
> www.peisch.com




Mike Gagnon


ENTIRE THREAD

sys(1037) =programtically Posted by Saifuddin Tehami @ 11/8/2006 12:16:57 PM
RE: sys(1037) =programtically Posted by Borislav Borissov @ 11/8/2006 12:26:33 PM
RE: sys(1037) =programtically Posted by Saifuddin Tehami @ 11/8/2006 12:57:16 PM
RE: sys(1037) =programtically Posted by Borislav Borissov @ 11/8/2006 1:10:47 PM
RE: sys(1037) =programtically Posted by Saifuddin Tehami @ 11/8/2006 1:17:45 PM
RE: sys(1037) =programtically Posted by Borislav Borissov @ 11/8/2006 1:33:17 PM
RE: sys(1037) =programtically Posted by Barbara Peisch @ 11/8/2006 8:20:50 PM
RE: sys(1037) =programtically Posted by Mike Gagnon @ 11/8/2006 8:55:58 PM
RE: sys(1037) =programtically Posted by Mike Gagnon @ 11/8/2006 2:26:08 PM
RE: sys(1037) =programtically Posted by Barbara Peisch @ 11/8/2006 9:14:17 PM
RE: sys(1037) =programtically Posted by Mike Gagnon @ 11/8/2006 9:37:38 PM